HI-5522 RESEARCH GRADE PH, ORP, ISE, EC, TDS, RESISTIVITY, SALINITY BENCH METER


HI-5522 RESEARCH GRADE PH, ORP, ISE, EC, TDS, RESISTIVITY, SALINITY BENCH METER

HI-5522 is a high grade bench top instrument that measures seven parameters. It incorporates dual channels with a separate temperature probe input and supports external reference electrodes required by half-cell pH sensors.

pH - Range  :                       -2.0 to 20.0 pH; -2.00 to 20.00; -2.000 to 20.000 pH

Resolution    :                 0.1 pH; 0.01 pH; 0.001 pH

Accuracy       :                ±0.1 pH; ±0.01 pH; ±0.002 pH ± 1 LSD

Calibration     :                automatic, up to five-point calibration, eight standard buffers available, and five custom buffers

Temperature Compensation:                 automatic or manual from -20.0 to 120.0°C

mV - Range                   :     ±2000 mV

Resolution                     :0.1 mV

Accuracy                      : ±0.2 mV ± 1 LSD

ISE - Range                  :       1 x 10-6 to 9.99 x 1010 concentration

Resolution                   :  1; 0.1; 0.01; 0.001 concentration

Accuracy                    :   ±0.5% (monovalent ions); ±1% (divalent ions)

Calibration                 :   automatic, up to five-point calibration, five fixed standard solutions available for each measurement unit, and five user efined standards

Temperature - Range :                   -20.0 to 120.0°C

Resolution      :               0.1°C

Accuracy        :                ±0.2°C (without probe)

EC - Range     :                    0.000 to 9.999 µS/cm; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm absolute EC

Resolution        :             0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm

Accuracy           :             ±1% of reading (±0.01µS/cm)

Cell Constant     :           0.0500 to 200.00

Cell Type            :            4 cells

Calibration          :           automatic standard recognition, user standard single point/multi-point calibration

Calibration Reminder:                yes

Temperature Coefficient:                        0.00 to 10.00%/°C

Temperature Compensation  :               disabled, linear and non-linear (natural water)

Reference Temperature          :               5.0 to 30.0°C

Profiles                     :      up to 10, 5 each channel

USP Compliant         :                   yes

TDS - Range             :          0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt actual TDS (with 1.00 factor)

Resolution                  :   0.001 ppm; 0. 01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt; 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt

Accuracy                     :   ±1% of reading (±0.01 ppm)

Resistivity - Range       :                   1.0 to 99.9 Ω • cm; 100 to 999 Ω • cm; 1.00 to 9.99 KΩ • cm; 10.0 to 99.9 KΩ • cm; 100 to 999 KΩ • 1.00 to 9.99 M Ω •cm; 10.0 to 100.0 MΩ • cm

Resolution   :                  0.1 Ω •cm; 1 Ω • cm; 0.01 K Ω •cm; 0.1 K Ω •cm; 1 KΩ • cm; 0.01 MΩ • cm; 0.1 MΩ • cm

Accuracy      :                  ±2% of reading (± 1 Ω • cm)

Salinity - Range:                practical scale: 0.00 to 42.00 psu; natural sea water scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0% NaCl

Resolution         :           0.01 for practical scalenatural sea water scale; 0.1% for percent scale

Accuracy            :           ±1% of reading

Calibration          :           percent-scale one point (with HI-7037 standard)

pH electrode        :             HI-1131B glass body pH electrode with BNC connector and 1m cable (included)

EC Probe              :               HI-76312 platinum, four-ring EC/TDS probe with a 1m cable (included)

Temperature Probe:                       HI-7662-T stainless steel temperature probe with 1m cable (included)

Input Channel (s)    :                        1 pH/ORP + 1 EC

GLP                   :    cell constant, reference temperature/coefficient, calibration points, calibration time stamp, probe offset for conductivity

Logging           :     record: 100,000 data point storage/channel, up to 100 lots with max, 50,000 records/lot; Interval: settable between 1 second and max log time of 180 minutes; Type: automatic, manual, AutoHOLD

Display            :     colour graphic LCD with on-screen help, graphing, and custom colour configuration

PC Connection:                 USB

Power Supply   :                12 VDC adapter (included)

Environment      :               0 to 50°C; RH max 95% non-condensing

Dimensions/Weight :                      160 x 231 x 94 mm/1.2 kg