Atomic Absorption Spectrophotometer (Flame Method) Model : SP-AA3608F


Atomic Absorption Spectrophotometer (Flame Method) Model : SP-AA3608F

Atomic Absorption Spectrophotometer Specifications:


Model  SP-AA3608F

Optical System Optical System Single Beam

               Monochromator             Czerny-Turner type, focal lengths at 350mm

               Grating Grating 1800 lines/mm, scintillation wavelength 250nm

               Spectral Bandwidth (nm)             0.1, 0.2, 0.4, 0.7, 1.4, 2nm Automated slit selection

               Wavelength Range (nm)              185-900nm

               Wavelength Accuracy(nm)         

0.2nm

               Wavelength Repeatability (nm) ≤0.1nm

               Spectral Bandwidth Deviation   ±0.02 nm

               Lamp Stand       

8

               Element Lamp Type       Cu lamp(Standard accessory)

Other element lamp is optional accessory

Photometric Performance          Reading Mode Transmittance, absorbance, concentration

               Photometric Range        0-125%,-0.1-3.00A

               Static Baseline Drift (Cu)              

±0.003A/30min

               Dynamic Baseline Drift (Cu)        ±0.005A/15min

               Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional)

Flame System   Characteristic Concentration (Cu)            

≤0.035ug/ml

               Detection Limit (Cu)       ≤0.006ug/ml

               Repeatability (Cu)           RSD≤0.6%

               Acetylene Flow Control Auto 12-Level

               Air Assist Control             Auto 4-Level

               Burner lift           Automatic lifting

               Burner Head     Titanium 100mm burner

               Nebulizer           High efficiency glass nebulizer

               Spray Chamber Corrosion-resistant material spray chamber

               Safety Protection            Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched

Data Processing               Measuring Method        Flame method, Hydride generation-Atomic absorption method, Flame emission method

               Concentration Calculation Method         Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method

               Repeat Measurement Times     1-30 times. Calculate and give the average value of absorbance/concentration. standard deviation and relative standard deviation

               Report Printing Parameter printing, Data result printing

Other   Computer          External connect

               Ambient Temp 10℃-30℃

               Ambient Humidity          40%-85%

               Power Supply   220/110V, 50/60HZ

               External Size (WxDxH)(mm)       830x650x560

               Shipping Size (WxDxH)(mm)      1000x780x810

               N.W./G.W. (kg) 90/110

               Standard Accessory       Software, Air compressor, Cu Hollow cathode lamp

               Optional Accessory        Computer, Printer, Hydride generator, Autosampler